Home » GAS MARKET » Technical Data

Technical Data

Measurement Volume Conversion Factor (VCF)

The calculation of the conversion factor C for each Delivery Point shall be carried out annually by the Operator within the first fifteen days of the year and shall be posted on the Operator’s website by Relative Distribution Network Entry Points and by operating pressure class

A. ENTRY POINT ATHENS

VCF @ (25 mbarg, 8,72 °C) VCF @ (100 mbarg, 8,72 °C) VCF @ (300 mbarg, 8,72 °C) VCF @ (500 mbarg, 8,72 °C)
0,990 1,062 1,252 1,443

Β. ENTRY POINT MARKOPOULO

VCF @ (25 mbarg, 9,86 °C) VCF @ (100 mbarg, 9,86 °C) VCF @ (300 mbarg, 9,86 °C)
0,987 1,058 1,248

A. ENTRY POINT ATHENS

VCF @ (25 mbarg, 8,55 °C) VCF @ (100 mbarg, 8,55 °C) VCF @ (300 mbarg, 8,55 °C) VCF @ (500 mbarg, 8,55 °C)
0,991 1,065 1,257 1,448

Β. ENTRY POINT MARKOPOULO

VCF @ (25 mbarg, 9,19 °C) VCF @ (100 mbarg, 9,19 °C) VCF @ (300 mbarg, 9,19 °C)
0,989 1,063 1,254
A. ENTRY POINT ATHENS

VCF @ (25 mbarg, 8,19 °C) VCF @ (100 mbarg, 8,19 °C) VCF @ (300 mbarg, 8,19 °C) VCF @ (500 mbarg, 8,19 °C)
0,992 1,067 1,259 1,450

Β. ENTRY POINT MARKOPOULO

VCF @ (25 mbarg, 9,42 °C) VCF @ (100 mbarg, 9,42 °C) VCF @ (300 mbarg, 9,42 °C)
0,988 1,062 1,253
A. ENTRY POINT ATHENS

VCF @ (25 mbarg, 9.03 °C) VCF @ (100 mbarg, 9.03 °C) VCF @ (300 mbarg, 9.03 °C) VCF @ (500 mbarg, 9.03 °C)
0,989 1,063 1,255 1,446

Β. ENTRY POINT MARKOPOULO

VCF @ (25 mbarg, 9.79 °C) VCF @ (100 mbarg, 9.79 °C) VCF @ (300 mbarg, 9.79 °C)
0,987 1,061 1,252
A. ENTRY POINT ATHENS

VCF @ (25 mbarg, 7,41 °C) VCF @ (100 mbarg, 7,41 °C) VCF @ (300 mbarg, 7,41 °C)
0,992 1,07 1,262

Β. ENTRY POINT MARKOPOULO

VCF @ (25 mbarg, 9,4 °C) VCF @ (100 mbarg, 9,4 °C) VCF @ (300 mbarg, 9,4 °C)
0,985 1,063 1,253

Typical Consumption Curves

Archive of Standard Consumption Profile values for the year

Mean Daily Average Values of Gross Calorific Value (GCV)

Read more about the values of the Mean Daily Average Values of Gross Calorific Value per Relative Distribution Network Entry Point

Mean Daily values of GCV